加载中···

E&I Technician 8k~10k

大专及以上 五年以上 浙江-宁波市

更新时间: 2024-11-30

中石化英力士苯领高新材料(宁波)有限公司
合资/合作 500 - 999人

职位要求

招聘日期: 2024-01-30 ~ 2024-12-31

职位描述

A. Purpose /Role of the job /: Describe in 1 phrase what contribution the job is expected to make to the organisation’s objectives

 The E&I shift technician is responsible for the trouble shooting and planned maintenance of the electrical, instrumentation and automation equipment and systems in the ISBL installations during the shift working hours, in order to ensure safe and reliable operations.

B. Environment/Context/Complexity of the job: Describe the most important internal and external factors influencing the job

Internal factors:
 Within E&I and mechanical maintenance team, mainly technicians
 With production team, production day supervisor, shift leader, operators

External factors:
 E&I contractors

C. Responsibilities/ Accountabilities of the job: Describe the main results expected from the job, sum up to 100%

SHE 25%:
• Participate on regular safety training at site:
o Safety rules and guidelines
o Operating procedures
o Incident sharing and learning
o Permit to work and Risk Assessment, etc.
• Active support to the safety culture at site and works safely for incident free operation.
• Understand and follow annual SHE improvement plan for the site.
• Work in line with SHE KPIs and Targets set by management from time to time.
• Contribute to Behaviour Based Safety (BBS) program at site.
o Participate on training at site to take BBSO to next level of reporting.
• Follow site procedures aligned with Company Guidance Notes (IGGNs).
• Accountable for
o Following and practicing Company 20 principles of Behaviour Safety and Process Safety at site through site rules and procedures
o Following and practicing Life Saving Rules at site
o Safety of other Employees, Contractors, Visitors and partners at site
o Following Permit to Work as per the site procedure
• Work in compliance with all legal regulations.
o Adherence to site licenses and permits.
• Participate on the Company Sustainability program at site.
• Stop work whenever there is an unsafe condition and immediately inform the Shift Leader and/or Head of Department.
• Directly intervene with those in your working area not using PPE or not following Company standards and procedures.
• Maintain the respective workplace in order and clean, as per best practices of housekeeping.

Electrical and Instrumentation Maintenance 50%:
• Solves electrical and electronic faults and performs preventive maintenance on the installations:
o looks at the occurrence of the malfunction
o travels on site and solves limited electrical and electronic faults (e.g. new motor fuses, repair position and pressure measurements, repair pump motor control), works for more complex tasks together with or under the supervision of the day E&I technicians
o puts the devices voltage-free, back on voltage, checks the measurements and the circuits on the installations (bridges if necessary)
o performs preventive automation maintenance on appliances, installations
o carries out the regularly recurring tests on safety circuits through strictly defined procedures and steps
• Contributes to implementation of changes to installations and processes (MOC):
• Installs new components or removes components that are no longer used, as part of the MOC process
• Pull cable, run conduit, and terminate electrical wiring per drawings.
• Repair/Replace AC/DC motors (480/4160 VAC) starters, (480/4160VAC) buckets, (480/4160 and up) switchgear, drives, relays, switches, instruments, breaker panels, etc., from low voltage to medium voltage. Troubleshoot and repair AC/DC electrical equipment, including all pneumatic, electric, heat tracing and fluid powered items on site.
• Read electrical drawings and use them to troubleshoot, install/replace electrical systems.
• Troubleshooting/replacement/calibration of Instrumentation (flow, pressure, temperature, level, position switches), process analyzers, LEL&Toxic gas detectors,...
• Repair actuated, quarter-turn valves with position indication.
• Troubleshoot Delta V and Siemens S7-1500 PLCs
• Repair Motor drives.
• Repair analysers, etc.
• Rebuild calibrate and troubleshoot control valves.
• Troubleshoot/replace and calibrate flow meters, level, pressure and temperature meters.
• Troubleshoot and repair actuated, quarter-turn valves with position indication.
• Troubleshoot and be able to read PLC programs.
• Troubleshoot, size, and replace electrical protection systems.
• Troubleshoot/replace lighting, floodlights and similar lighting equipment fixtures.
• Perform other duties as assigned which may not be specifically listed in the position description, but which are within general occupational duties and responsibility level typically associated with the employee’s skills.
• Maintain good housekeeping in the field and E&I maintenance shop and warehouse
3rd party contractor 5%:
• Support the work activities of electrical contractors.
Documentation, Database 10%
• Register own activities administratively
• Follows the PTW according the procedures.